Installation for Model WB-3000


COLD
installation
Fig 1:
- Remove Toilet seat and existing nutsbyusing screwdriver. Install coupling holes to center of the toilet. Set adjusters. Install toilet seat back in place and fasten existing screws.
HOT
and COLD
installation
| Fig 2: | Fig 3: |
![]() |
|
- Turn Off hot water to washbowl and remove existing nut and tube by using a wrench connected adapter to hot water valve by using thread seal tape (T eflon tape) and holding down the back tube from wall with a grip plyers. (Fig 2)
- Fasten adaptors with wrench until secure and connect 3/8" flexible hose from adapter to faucet tube w/pigtail 3/8" comp. valve.
- Fasten adaptors with wrench until secure and connect 3/8" flexible hose from adapter to faucet tube w/pigtail 3/8" comp. valve.
Note: Be careful not to break the incoming water line
Assembled Figure:
Fig 4:
Two types connector
- Hot water flexible hose to valve 3/8" compression to faucet w/pigtail 3/8" compression.
- Hot water flexible hose to valve 3/8" compression to faucet 1/2" pipe thread.
Note: Please check temperature controls before use, as the temperature varies every day is not the same for every house, check the water temperature before use as it may be too hot or too cold.
Installation for Model Fresh Bidet
Step 1: accessories
All accessories are included in the product box.
| A. Bidet Body | B. Adapter | C. (2) PVC Tubes |
D. Rubber Band |
![]() |
![]() |
![]() |
![]() |
| E. (2) Rubber Pads | F. (2) Rubber Packing | G. (2) T Bolt & Nut | H. Flexable Stanless Pipes |
![]() |
![]() |
![]() |
![]() |
Step 2: Remove the original toilet seat
- Turn and loosen the nuts under toilet seat.
- Remove the original toilet seat.
- Put 2 T-bolts to the bidet like figre A.
- Put the rubber pad on your basin toilet.
- Put the bidet on your basin toilet.
- Rubber packing to be fit into T-bolt.
- Fix the nuts strictly.
Step 3: How to connect pipes between bidet worm/cold water pipes
- Close the valve of warm/cold water under the bowel lavatory.
- Loosen nuts of the pipes and remove the original pipes by spanner.
- Put the rubber packing (F) into the adapter and connect pipes (H) which are provided in the box then fix the pipes to each valve.
- PVC tubes are to be put into the adapters.
If you have any question or concern, please email us at: